| Flow rate transmitters |
 |
|
 |
Ideal for batching, industrial process control, mobile hydraulic equipment and computer/PLC-controlled hydraulic system monitoring applications.
Simple to install: All transmitters are factory calibrated and ship fully assembled. Simply install the transmitter into your system and apply power.
Industry standard outputs: Transmitters provide proportional analog outputs of 4-20mA, 0-5 Vdc and 1-5 Vdc1, and 20-2000 Hz square-wave pulse. These outputs will drive popular data acquisition devices, meters and analog input cards.
Direct reading:
All transmitters provide a visual indication of flow rate proportional to the transmitted output.
Weather-tight construction: The rugged cast aluminum NEMA type 4X enclosure allows installation in outdoor applications and in environments where liquid tight seals are required.
Rugged and reliable: Without delicate internal components to break, abrade or corrode, the Lake flow transmitter will provide many years of low-maintenance service.
Compatible with lake monitors R/T100 and R100 flow analyzers:
The Lake flow rate transmitter combines with these Lake analyzers to make a powerful flow instrument capable of remote monitoring of rate and total flows.
1The 1-5Vdc output requires an external 249 ohm resistor (not included with transmitter) to be wired at the receiving device.
|
Flow Transmitter Engineering specifications:
The in-line Flow Rate Monitor/Transmitter Shall:
Be factory calibrated for 4-20mA, 0-5Vdc, 1-5Vdc, and square wave pulse outputs
Use the variable annular orifice technique with compression spring recoil
Not require inlet or outlet straight plumbing, or require vertical orientation
Have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% in upper and lower thirds
Have a stainless steel sharp-edged orifice
Have a maximum working pressure rating of 3500 or 6000 PSIG for liquids
Have a maximum working pressure rating of
600 or 1000 PSIG for gasses
Have a weather-tight external construction
Be Lake Monitors No. R _ _ – _ _ _ – _ _
| Flow Transmitter Materials of Construction (Wetted Components) |
| |
Aluminum |
Brass |
Stainless steel |
| High-pressure casing, end ports and tapered shaft |
Aluminum |
Brass |
303 Stainless steel |
| Seals |
Buna-N (STD), EPR, Viton or Kalrez |
Buna-N (STD), EPR, Viton or Kalrez |
Viton® with Teflon® backup (STD.), Buna-N,
EPR or Kalrez |
| Transfer Magnet |
Teflon coated Alnico |
Teflon coated Alnico |
Teflon coated Alnico |
| Floating Orifice disk |
Stainless Steel |
Stainless Steel |
Stainless Steel |
| All other internal parts |
Stainless Steel |
Stainless Steel |
Stainless Steel |
| Materials of Construction (Non-Wetted Components) |
| |
Aluminum |
Brass |
Stainless Steel |
| Enclosure & Cover |
Aluminum |
Aluminum |
Aluminum |
| Seals |
Buna-N |
Buna-N |
Buna-N |
| Window |
Pyrex |
Pyrex |
Pyrex |
| Din connector |
Polyamide |
Polyamide |
Polyamide |
| Meter Performance |
| Measuring accuracy |
±2.5% of full-scale in the center third of the measuring range; ±4% in upper and lower thirds |
| Repeatability |
±1% of full-scale |
| Flow measuring range |
0.05-150 GPM (0.2-560 LPM); 1.5-1300, SCFM (0.75-610 SLPS) |
| Maximum operating pressure |
aluminum and brass meters: 3500 PSIG (240 Bar)
stainless steel meters: 6000 PSIG (410 Bar) |
| Maximum operating temperature |
media: 240°F (116°C), ambient: 180°F (82°C) |
| Standard calibration fluids |
Oil meters: DTE 25® @ 110°F (43°C), 0.873 sg
Water metes: tap water @ 70°F (21°C), 1.0 sg
Air meters: air @ 70°F (21°C), 1.0 sg and 100 PSIG (6.8 Bar) |
| Filtration requirements |
74 micron filter or 200 mesh screen minimum |
| Electronic Transmitter Performance |
| Power requirements |
12-35 Vdc |
| Load driving capacity |
4-20mA: Load resistance is dependent on power supply voltage. Use the following equation to calculate maximum load resistance:
Max Loop Load (Ω) = 50(Power supply volts - 12).
0-5 VDC: Minimum load resistance 1000 Ω
1-5 VDC: Minimum load resistance 25 K Ω
Square Wave Pulse: Minimum load resistance 1000 Ω |
| Transmission distance |
4-20mA and 1-5 VDC are limited only by wire resistance and power supply voltage.
<200 feet recommended for 0-5 VDC and square wave pulse |
| Over-current protection |
self limiting at 35mA |
| Resolution |
10 bit (0.1%) |
| Isolation |
Inherently isolated from the process |
| Response time |
<100 milliseconds |
| Mechanical size code |
 |
| DIM |
Series 3 |
Series 4 |
Series 5 |
Series 5 |
| A |
6-9/16"
(167mm) |
7-5/32"
(182mm) |
10-1/8"
(258mm) |
12-5/8"
(322mm) |
| B |
2-3/16"
(56mm) |
2-15/16"
(75mm) |
3-13/16"
(97mm) |
3-13/16"
(97mm) |
| C |
4"
(101mm) |
4-1/2"
(114mm) |
5-5/16"
(135mm) |
5-5/16"
(135mm) |
| D |
1-7/8"
(47mm) |
1-7/8"
(47mm) |
1-7/8"
(47mm) |
1-7/8"
(47mm) |
| E |
4-7/8"
(128mm) |
5"
(127mm) |
6-3/4"
(172mm) |
6-3/4"
(172mm) |
| F |
2-1/4"
(57mm) |
2-7/8"
(73mm) |
3-3/4"
(95mm) |
3-3/4"
(95mm) |
| Port Size |
NPTF: 1/4", 3/8", 1/2"
SAE: #6, #8, #10
BSP: 3/8", 1/2" |
NPTF: 3/4", 1"
SAE: #12, #16,
BSP: 3/4", 1" |
NPTF: 1-1/4", 1-1/2"
SAE: #20, #24
BSP: 1-1/4", 1-1/2" |
NPTF: 2"
SAE: #32
BSP: 2" |
|
 |
|
 |
|
 |
Download for more information |
| PDF files contain much more in-depth information about this product |
|
|