Reliability
M-Series meters are
designed to contain very few wearable and
replaceable parts. Meter construction enables fast
and easy on-site servicing without the need to
remove the body from the pipe work.
M1
& M2
low flow models
The smallest models
in the M-Series range provide low cost high
resolution pulse meters capable of measuring fluids
with viscosity's from 1 to 1000 centipoise. Body
and rotor materials are either PPS or 316 S/Steel
with Hastalloy C shafts available for extremely
aggressive chemicals. Pulse output is either Hall
effect or reed switch.
|
|
|
|
|
|
M5
to M50
small to high flow models
Higher pressure
ratings than the standard M1 & M2 as well as a
variety of connection types, pulse output and
display options make for a high degree of diversity
among the rest of the models within the M-Series
range.
Aluminium or 316 S/steel bodies and a choice of PPS
or S/Steel rotors are some of the options designed
to help you tailor the flow meter to your
particular needs. All models feature exceptionally
low pressure drops of less than 1 Bar at full flow
allowing for economical pump selection or gravity
fed applications.
Head mounted and
remote display options specific to M-Series meters
are available, although various output options
ensure M-Series meters are compatible with many
types of third party instrumentation.
Applications
M-Series meters
will accurately measure, mix, batch and dose an
extremely wide variety of fluid mediums including
aggressive and intrinsically safe applications. A
choice of construction and sealing materials
coupled with high viscosity and high temperature
options enable the engineer to select a model which
is tailored to the application at hand.
|
|
|
|
|
M1
Series 1/4" Flow Meters
|
|

|
M1 - 1/4" Pulse
Meters
The M1 is the
smallest capacity meter in the range. An excellent
turn-down 100:1 and high resolution (1 pulse per
cc) make this meter an ideal choice for accurate
low flow metering.
It has the ability
to handle a wide range of fluid viscosities with
exceptional levels of repeatability and
durability.
A New high pressure
M1 (551 bar) has recently been
introduced
|
>
M2 0.25 to 8.33
Litres/min
>
M4 1 to 30 Litres/min
>
M7 3 to 80 Litres/min
>
M10 6 to 120
Litres/min
>
M40 10 to 250
Litres/min
>M50
15 to 350 Litres/min
>
Accessories
>
Displays
>Top
of page
|
|
|
|
|
|
Model
|
M1RSP-XY
|
M1SSP-XY
|
M1SSPH-X
|
|
Meter
Type
|
Pulse
|
Pulse
|
Pulse
|
|
Meter Body
Material
|
PPS
|
316
Stainless Steel
|
316
Stainless Steel
|
Wetted
Components:
|
|
Rotor
Material
|
316 S/St
or PPS option
|
316
Stainless Steel
|
316
Stainless Steel
|
|
Shafts
|
316
St/Steel or Hastalloy Opt
|
316
Stainless Steel
|
316
Stainless Steel
|
|
O'ring
|
Viton-
Standard
|
Viton-
Standard
|
Viton-
Standard
|
Flow Rate
Ranges (litres per hour/US gallons per
hour)
|
|
Above 5
CPS
|
2 to 100 /
0.53to 26.4
|
2 to 100 /
0.53 to 26.4
|
2 to 100 /
0.53to 26.4
|
|
Below 5
CPS
|
5 to 100 /
1.32 to 26.4
|
5 to 1007
/ 1.32 to 26.4
|
5 to 100 /
1.32 to 26.4
|
|
Accuracy
within (of reading)
|
+/-
1%
|
+/-
1%
|
+/-
1%
|
|
Repeatability
|
0.03%
|
0.03%
|
0.03%
|
|
Maximum
Viscocity
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
|
Maximum
Operating Pressure
|
500kPa/ 75
PSI/ 5 BAR
|
1000kPa/
150PSI/ 10BAR
|
55160kPa/
8000PSI/ 551BAR
|
|
Pulser
Type
|
Hall
Effect Sensor or Reed Switch
|
Hall
Effect Sensor or Reed Switch
|
Hall
Effect Sensor
|
|
Pulses per
litre/US Gallon
|
1000 /
3785.4
|
1000 /
3785.4
|
1000 /
3785.4
|
Model
Dimensions
|
|
Meter
Body
|
50x50mm /
1.97"x1.97"
|
50x50mm /
1.97"x1.97"
|
86mm dia x
110mm h / 3.4" dia x 4.33" h
|
|
Port face
to face
|
65mm /
2.58"
|
65mm /
2.58"
|
83mm /
3.26"
|
|
Weight
|
240g /
8.5oz
|
600g /
21.2oz
|
3.3kg /
116.5oz
|
|
Max.
Operating Temperature
|
80°C
/ 176°F
|
120°C
/ 248°F
|
120°C
/ 248°F
|
|
Recommended
Mesh
strainer size
|
200
Mesh
|
200
Mesh
|
200
Mesh
|
|
M2
Series 1/4" Flow Meters
|
|

|
M2 - 1/4" Pulse
Meters
The M2 is one of
the small capacity meters in the range . It has a
low to medium flow range which has made it a very
popular model.
It has the ability
to handle a wide range of fluid viscosities with
exceptional levels of repeatability and
durability
A New high pressure
M2 (551 bar) has recently been
introduced
|
>
M1 0.03 to 1.6
Litres/min
>
M4 1 to 30 Litres/min
>
M7 3 to 80 Litres/min
>
M10 6 to 120
Litres/min
>
M40
10 to 250 Litres/min
>
M50
15 to 350 Litres/min
>
Accessories
>
Displays
>
Top of page
|
|
|
|
|
|
Model
|
M2RSP-XY
|
M2SSP-XY
|
M2SSPH-XY
|
|
Meter
Type
|
Pulse
|
Pulse
|
Pulse
|
|
Meter Body
Material
|
PPS
|
316
Stainless Steel
|
316
Stainless Steel
|
Wetted
Components
|
|
Rotor
Materials
|
316
St/Steel or PPS Option
|
316
Stainless Steel
|
316
Stainless Steel
|
|
Shafts
|
316
St/Steel or Hastalloy Opt
|
316
Stainless Steel
|
316
Stainless Steel
|
|
O'ring
|
VITON-
Standard
|
VITON-
Standard
|
VITON-
Standard
|
Flow Rate
Ranges (litres per hour/US gallons per
hour)
|
|
Above 5
CPS
|
15 to 500
/ 4 to 132
|
15 to 500
/ 4 to 132
|
15 to 500
/ 4 to 132
|
|
Below 5
CPS
|
25 to 500
/ 6 to 132
|
25 to 500
/ 6 to 132
|
25 to 500
/ 6 to 132
|
|
Accuracy
within (of reading)
|
+/-
1%
|
+/-
1%
|
+/-
1%
|
|
Repeatability
|
0.03%
|
0.03%
|
0.03%
|
|
Maximum
Viscosity
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
|
Max.
Operating Pressure
|
500kPa/ 75
PSI/ 5 BAR
|
1000kPa/
150PSI/ 10BAR
|
551600kPa/
8000PSI/ 551BAR
|
|
Pulser
type
|
Hall
Effect Sensor or Reed Switch
|
Hall
Effect Sensor or Reed Switch
|
Hall
Effect Sensor
|
|
Pulses per
litre/US Gallon
|
400 /
1514.2
|
400 /
1514.2
|
400 /
1514.2
|
Model
Dimensions
|
|
|
|
|
Meter
Body
|
50x50mm /
1.97"x1.97"
|
50x50mm /
1.97"x1.79"
|
86mm dia x
110mm h
3.4" dia x 4.33" h
|
|
Port Face
to Face
|
65mm /
2.58"
|
65mm /
2.58"
|
83mm /
3.26"
|
|
Weight
|
240g /
8.5oz
|
600g /
21.2oz
|
3.3kg
/116.5oz
|
|
Max.
Operating Temperature
|
80°C
/ 176°F
|
120°C
/ 248°F
|
120°C
/ 248°F
|
|
Recommended
Mesh Strainer Size
|
200
Mesh
|
200
Mesh
|
200
Mesh
|
|
M4
Series - 1/2" Flow Meters
|
|
The M5 series are
the small to medium capacity meters in the
Macnaught range. They have the ability to handle a
wide range of fluid viscosities with exceptional
levels of repeatability and durability. EEx d
Certified
Optional features
include:
- Dual pulse
output
- Analogue
output
- High viscosity
rotors (up to1,000,000 Centipoise)
- Head-mounted
Rate/Totaliser and Batch controller LCD Display
(EEx ia 0ption)
- Mechanical
Display option
|
>
M1 0.03 to 1.6
Litres/min
>
M2 0.25 to 8.3
Litres/min
>
M7 3 to 80 Litres/min
>
M10 6 to 120
Litres/min
>
M40 10 to 250
Litres/min
>
M50 15 to 350
Litres/min
>
Accessories
>
Displays
>
Top of page
|
|
|

|
|
Model
|
M4ARP-X
|
M4ASP-X
|
M4SRP-X
|
M4SSP-X
|
|
Meter
Type
|
Pulse
|
Pulse
|
Pulse
|
Pulse
|
|
Meter Body
Material
|
AA601
Aluminium
|
AA601
Aluminium
|
316
Stainless Steel
|
316
Stainless Steel
|
Wetted
Components
|
|
|
Rotor
Material
|
PPS
|
316
Stainless Steel
|
PPS
|
316
Stainless Steel
|
|
Shafts
|
316
Stainless Steel
|
316
Stainless Steel
|
316
Stainless Steel
|
316
Stainless Steel
|
|
O'ring
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
Flow Rate
Ranges (litres per minute/US gallons per
minute)
|
|
Above 5
CPS
|
1 to 30 /
0.26 to 8
|
1 to 30 /
0.26 to 8
|
1 to 30 /
0.26 to 6.60
|
1 to 30/
0.26 to 8
|
|
Below 5
CPS
|
3 to 25 /
0.8 to 6.60
|
3 to 25 /
0.8 to 6.60
|
3 to 25 /
0.8 to 6.60
|
3 to 25 /
0.8 to 6.60
|
|
Accuracy
within (of reading)
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
|
Repeatability
|
0.03%
|
0.03%
|
0.03%
|
0.03%
|
|
Maximum
Viscosity (of standard model)
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
|
Maximum
Operating Temperature
|
5500kPa/
800 PSI/ 55 BAR
|
5500kPa/
800 PSI/ 55 BAR
|
5500kPa/
800 PSI/ 55 BAR
|
5500kPa/
800 PSI/ 55 BAR
|
|
Pulser
Type
|
Hall
Effect or Reed Switch or Combination HE /
RS
|
Hall
Effect or Reed Switch or Combination HE /
RS
|
Hall
Effect or Reed Switch or Combination HE /
RS
|
Hall
Effect or Reed Switch or Combination HE /
RS
|
|
Pulses per
litre/US Gallon
|
81 OR 162
/ 306.6 0R 613.2
|
81 OR 162
/ 306.6 0R 613.2
|
81 OR 162
/ 306.6 0R 613.2
|
81 OR 162
/ 306.6 0R 613.2
|
Model
Dimensions
|
|
Meter
Body
|
112mm dia
x 125mm h
4.41" dia x 4.92" h
|
112mm dia
x 125mm h
4.41" dia x 4.92" h
|
112mm dia
x 125mm h
4.41" dia x 4.92" h
|
112mm dia
x 125mm h
4.41" dia x 4.92" h
|
|
Port Face
to Face
|
125mm /
4.92"
|
125mm /
4.92"
|
125mm /
4.92"
|
125mm /
4.92"
|
|
Weight
|
1.8kg /
3.96lbs
|
1.8kg /
3.96lbs
|
2.9kg /
6.39lbs
|
2.9kg /
6.39lbs
|
|
Max.
Operating Temperature
|
80°C
/ 176°F
|
120°C
/ 248°F
|
80°C
/ 176°F
|
120°C
/ 248°F
|
|
Recommended
Mesh
Strainer Size
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
|
|
M7
Series - 1" Flow Meter - SUPER ACID PROOF
METER
|
|

|
The M7 series is
the meter of choice for low cost metering of acids
or water based liquids.
Prices from
£335.00
Optional features
include:
- Dual pulse
output
- Analogue output
- High viscosity
rotors (up to1,000,000 Centipoise)
- High
temperature version available
- Head mounted or
remote LCDs
- IS versions
available
-

|
>
M1 0.03to 1.6
Litres/min
>
M2 0.25 to 8.3
Litres/min
>
M4 1 to 30Litres/min
>
M10 6 to 120
Litres/min
>
M40 10 to 250
Litres/min
>
M50 15 to 350
Litres/min
>
Accessories
>
Displays
>
Top of page
|
Model
|
M7APP-X
|
|
Meter
Type
|
Pulse
|
|
Meter Body
Material
|
PPS
|
Wetted
Components
|
|
Rotor
Material
|
PPS
|
|
Shafts
|
PPS
|
|
O'ring
|
VITON
|
Flow Rate Ranges
litres per minute
|
|
Above 5
CPS
|
3 to 80
L/min
|
|
Below 5
CPS
|
8 to 70
L/min
|
|
Accuracy within (of
reading)
|
+/- 0.5%
|
|
Repeatability
|
0.03%
|
|
Maximum Viscosity
(of standard model)
|
1000
Centipoise
|
|
Maximum Operating
Temperature
|
5500kPa/ 800 PSI/
55 BAR
|
|
Pulser
Type
|
Hall Effect or Reed
Switch or Combination HE / RS
|
|
Pulses per
litre
|
52 OR
104
|
Model
Dimensions
|
|
Meter
Body
|
100mm dia x 120mm
h
|
|
Port Face to
Face
|
108mm /
4.92"
|
|
Weight
|
0.9kg
|
|
Max. Operating
Temperature
|
80°C
|
|
Recommended
Mesh
Strainer Size
|
60 Mesh
|
M10
- 1" Flow Meters
|
|
The M10 series are
the small to medium capacity meters in the
Macnaught range. They have the ability to handle a
wide range of fluid viscosities with exceptional
levels of repeatability and durability. EEx d
Certified
Optional features
include:
- Dual pulse
output
- Analogue
output
- High viscosity
rotors (up to1,000,000 Centipoise)
- Head-mounted
Rate/Totaliser and Batch controller LCD Display
(EEx ia option)
- Mechanical
register option
-

|
>
M1 0.03 to 1.6
Litres/min
>
M2 0.25 to 8.3
Litres/min
>
M4 1 to 30 Litres/min
>
M7 3 to 80 Litres/min
>
M40 10 to 250
Litres/min
>
M50 15 to 350
Litres/min
>
Accessories
>
Displays
>
Top of page
|
|
Model
|
M10ARE-X
|
M10ASE-X
|
M10SRE-X
|
M10SSE-X
|
M10BRE-X
|
|
Meter
type
|
Pulse with
delux LC display
|
Pulse with
delux LC display
|
Pulse with
delux LC display
|
Pulse with
delux LC display
|
Pulse with
delux LC display
|
|
Meter body
material
|
AA601
Aluminium
|
AA601
Aluminium
|
316
Stainless steel
|
316 316
Stainless steel
|
Bronze
|
Wetted
components:
|
|
Rotor
Material
|
PPS
|
316
Stainless steel
|
PPS
|
316
Stainless steel
|
PPS
|
|
Shafts
|
316
Stainless steel
|
316
Stainless steel
|
316
Stainless steel
|
316
Stainless steel
|
316
Stainless steel
|
|
O'Ring
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
Flow Rate
Ranges (litres per minute/US gallons per
minute)
|
|
Above 5
CPS
|
6 to 120 /
1.6 to 32
|
6 to 120 /
1.6 to 32
|
6 to 120 /
1.6 to 32
|
6 to 120 /
1.6 to 32
|
6 to 120 /
1.6 to 32
|
|
Below 5
CPS
|
10 to 100
/ 2.6 to 26
|
10 to 100
/ 2.6 to 26
|
10 to 100
/ 2.6 to 26
|
10 to 100
/ 2.6 to 26
|
10 to 100
/ 2.6 to 26
|
|
Accuracy
within (of reading)
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
|
Repeatability
|
0.03%
|
0.03%
|
0.03%
|
0.03%
|
0.03%
|
|
Maximum
viscocity of standard model
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
|
Maximum
operating pressure
|
5500kPa/
800 PSI/ 55 BAR or flange rule where
fitted
|
|
Pulser
type
|
Reed
switch or combination HE / RS
|
Reed
switch or combination HE / RS
|
Reed
switch or combination HE / RS
|
Reed
switch or combination HE / RS
|
Reed
switch or combination HE / RS
|
|
Pulses per
litre/
US gallon
|
36
/136.3
|
36
/136.3
|
36
/136.3
|
36
/136.3
|
36
/136.3
|
|
Max.
operating temperature
|
80°C
/ 176°F
|
120°C
/ 248°F
|
80°C
/ 176°F
|
120°C
/ 248°F
|
80°C
/ 176°F
|
|
Recommended
mesh strainer size
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
|
M40
- 1.5" Flow Meters
|
|
The M40 series are
medium capacity meters in the Macnaught range. They
have the ability to handle a wide range of fluid
viscosities with exceptional levels of
repeatability and durability. EEx d
Certified
Optional features
include:
- Dual pulse
output
- Analogue
output
- High viscosity
rotors (up to1,000,000 Centipoise)
- Head-mounted
Rate/Totaliser and Batch controller LCD Display
(EEx ia option)
- Mechanical
register option
-

|
>
M1 0.03 to 1.6
Litres/min
>
M2 0.25 to 8.3
Litres/min
>
M4 1 to 30 Litres/min
>
M7 3 to 80 Litres/min
>
M10 6 to 120
Litres/min
>
M50 15 to 350
Litres/min
>
Accessories
>
Displays
>
Top of page
|
|
Model
|
M40ARP-X
|
M40ASP-X
|
M40SRP-X
|
M40SSP-X
|
|
Meter
type
|
PULSE
|
PULSE
|
PULSE
|
PULSE
|
|
Meter body
material
|
AA601
Aluminium
|
AA601
Aluminium
|
316
Stainless steel
|
316
Stainless steel
|
Wetted
components
|
|
Rotor
material
|
PPS
|
316
Stainless steel
|
PPS
|
316
Stainless steel
|
|
Shafts
|
316
Stainless steel
|
316
Stainless steel
|
316
Stainless steel
|
316
Stainless steel
|
|
'O'Ring
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
Flow rate
ranges (litres per minute/US gallons per
minute)
|
|
Above 5
CPS
|
10 to 250
/ 2.6 to 66
|
10 to 250
/ 2.6 to 66
|
10 to 250
/ 2.6 to 66
|
10 to 250
/ 2.6 to 66
|
|
Below 5
CPS
|
15 to 235
/ 4 to 62
|
15 to 235
/ 4 to 62
|
15 to 235
/ 4 to 62
|
15 to 235
/ 4 to 62
|
|
Accuracy
within (of reading)
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
+/-
0.5%
|
|
Repeatability
|
0.03%
|
0.03%
|
0.03%
|
0.03%
|
|
Maximum
viscosity of standard model
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
1000
Centipoise
|
|
Maximum
operating pressure
|
5500kPa/
800 PSI/ 55 BAR or flange rule where
fitted
|
|
Pulser
type
|
Hall
effect or Reed switch or combination HE /
RS
|
Hall
effect or Reed switch or combination HE /
RS
|
Hall
effect or Reed switch or combination HE /
RS
|
Hall
effect or Reed switch or combination HE /
RS
|
|
Pulses per
litre/US gallon
|
14.5 OR 29
/ 54.9 0R 109.8
|
14.5 OR 29
/ 54.9 0R 109.8
|
14.5 OR 29
/ 54.9 0R 109.8
|
14.5 OR 29
/ 54.9 0R 109.8
|
|
Maximum
operating temperature
|
80°C
/ 176°F
|
120°C
/ 248°F
|
80°C
/ 176°F
|
120°C
/ 248°F
|
|
Recommended
mesh strainer size
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
60
Mesh
|
|
M50
- 2" Pulse Meters
|
|
>
M1 0.03 to 1.6
Litres/min
>
M2 0.25 to 8.3
Litres/min
>
M4 1 to 30 Litres/min
>
M7 3 to 80 Litres/min
>
M10 6 to 120
Litres/min
>
M40 10 to 250
Litres/min
>
Accessories
>
Displays
>
Top of page
|
|
The M50 series are
the high capacity meters in the Macnaught range.
They have all the benefits of the smaller models
with extra mechanical options.
|
|
|

|
|
Model
|
M50ARP-X
|
M50SRP-X
|
|
Meter
Type
|
Pulse
|
Pulse
|
|
Meter Body
Material
|
AA601
Aluminium
|
316
Stainless Steel
|
Wetted
Components
|
|
Rotor
Material
|
PPS
|
PPS
|
|
Shafts
|
316
Stainless Steel
|
316
Stainless Steel
|
|
O'ring
|
NBR
(Nitrile)
|
NBR
(Nitrile)
|
FlowRate
Ranges (litres per minute/US gallons per
minute)
|
|
Above 5
CPS
|
15 to 350
/ 3.96 to 92.46
|
15 to 350
/ 3.96 to 92.46
|
|
Below 5
CPS
|
30 to 300
/ 7.93 to 79.25
|
30 to 300
/ 7.93 to 79.25
|
|
Accuract
within (of reading)
|
+/-
0.5%
|
+/-
0.5%
|
|
Repeatability
|
0.03%
|
0.03%
|
|
Maximum
Viscosity (of Standard Model)
|
1000
Centipoise
|
1000
Centipoise
|
|
Maximum
Operating Pressure
|
As per
flange rule
|
As per
flange rule
|
|
Pulser
Type
|
Hall
Effect or Reed Switch
or combination HE / RS
|
Hall
Effect or Reed Switch
or combination HE / RS
|
|
Pulses per
litre/US Gallons
|
6.68 /
25.29
|
6.68 /
25.29
|
|
Max.
Operating Temperature
|
80°C
/ 176°F
|
80°C
/ 176°F
|
|
Recommended
Mesh Strainer Size
|
60
Mesh
|
60
Mesh
|
|
Accessories
|
|
|
|
>
M1 0.03 to 1.6
Litres/min
>
M2 0.25 to 8.3
Litres/min
>
M4 1 to 30 Litres/min
>
M7 3 to 80 Litres/min
>
M10 6 to 120
Litres/min
>
M40 10 to 250
Litres/min
>
M50 15 to 350
Litres/min
>Displays
>
Top of page
|
Optional
O'rings
|
|
Various optional
O'Rings are available for the M Series range to
allow the flowmeters to have maximum flexibility in
most applications.
For the M1
and M2,
both EPDM and Teflon encapsulated O'Rings are
available. The M4,
M10,
M40
and M50
are
available with Viton, EPDM and Teflon encapsulated
O'Rings.
|
Optional - High
Temperature Rotors
|
|
For fluid
temperatures above 80°C/176°F and up to
120°C/248°F, operators may select 'high
temperature' rotors. This option only applies for
the PPS rotor models of the M4,
M10,
M40
and M50
as meters fitted with stainless steel rotors are
capable of handling temperatures up to
120°C/248°F. (Except mechanical version
which are limited to
80°C/176°F).
|
Optional - High
Viscosity Rotors
|
|
For fluids above
1000cps, viscosity, optional high viscosity PPS or
stainless steel rotors can be specified for
M4,
M10,
M40
and M50
(PPS only) models. If necessary consult your local
distributor for additional technical assistance as
the flow rate will vary in accordance with fluid
viscosity (See page 26).
|
Optional - Hall
Effect Sensor
|
|
The
M4,
M10,
M40
and M50
pulse models can be optionally fitted with two
digital output Hall Effect Switches to eliminate
oscillation (pulse bounce) experienced with
standard reed switches.
The HE Switches are 3-wire solid state NPN output
devices with 4.5 - 24-volt DC supply voltage
ratings. A common power supply must be used.
Note: When Hall Effect Sensors are fitted, only the
lesser pulse output is available although the two
sensors can be used for dual outputs. A single Hall
Effect Sensor is standard on M1
and M2
models.
|
Optional - Solvent
Kit (Mechanical display meters only)
|
|
Mechanical versions
of the M10, M40 and M50 aluminium models can be
fitted with a special seal kit for use with most
common solvents. This kit is standard on all
stainless steel mechanical models.
|
Optional -
Hastalloy C Shafts
|
|
Special Hastalloy C
Shafts are available for the M1
and M2
PPS body meters for use with extremely aggressive
chemicals.
|
Accessory -
Extended Life Battery
|
|
DELUXE LC DISPLAY
ONLY
A silicon protection boot is available when the
meter is used in an aggressive atmosphere.
Accessory part number is B500.
|
Accessory - Head
Mounted or Remote Mounted LC Displays
|
|
These displays can
be head mounted on to M-Series pulse meters
originally supplied without a display, or supplied
with mounting brackets and mounted remotely. They
can be connected also to the auxiliary pulse output
of a local display meter for use as a second remote
display. Accessory part numbers are F500 (deluxe
version EEx ia Rate/Total + batching
facilities) and G500 (standard version Rate/Total +
Re-set)
DELUXE LC DISPLAY
ONLY
The service life of the battery supplied in the
deluxe display is approximately one
year.
This replacement
Lithium 3-volt (CR123A) extended life battery will
approximately double the service period but the
"intrinsically safe" feature will be lost.
Accessory part number is L500.
|
Displays
|
|
>
Standard LC Display
>
Deluxe LC Display
>
Mechanical Display
|
>
Meters
>
Accessories
>
Top of page
|
|
|
Standard
LC Display
|
|

>
Deluxe LC Display
>
Mechanical Display
>
Meters
>
Accessories
>
Top of page
|
The standard LC
Display is available on specific M4,
M10,
M40
and M50
series models. It is also available as an accessory
so it can be used as a remote mounted display for
any M Series meter model supplied without a display
e.g. M1,
M2,
M10
etc.
Features
- 8 Digit x10mm/
3/8" Liquid Crystal Display.
- Display can be
rotated in 90° steps.
- Flow rate
display in litres or US gallons (according to
model selected).
- 2 total
displays - resettable and non-resettable, up to
999,999.99 litres or US gallons (according to
model selected).
- Factory set
calibration constant (K factor).
- Long life
9-volt Lithium battery.
- Pulse output
for ancillary equipment.
|
Deluxe
LC Display
|
|

>
Standard LC Display
>
Mechanical Display
>
Meters
>
Accessories
>
Top of page
|
The deluxe LC
Display is available on specific M4,
M10,
M40
and M50
series models. It is also available as an accessory
so it can be used as a remote mounted display for
any M Series meter model supplied without a display
e.g. M1,
M2, M10
etc.
Features
- 7 Digit x
12.7mm (1/2") Liquid Crystal
Display.
- Display can be
rotated in 90° steps.
- Selectable flow
rate display in litres or US
gallons.
- 2 total
displays.
- Up to 999,999.9
litres or US gallons (resettable).
- Pre-settable
batch control function up to 9,999 units (99.99,
999.9 or 9,999 optional settings).
- 10 preset batch
quantity storage capacity.
- 3 digit cycle
counter for batch dispensed.
- Single or two
stage valve actuation output to be used with
appropriate trip amplifier.
- Factory set
calibration constant (K Factor).
- Additional 9
calibration constants (K Factors) available for
"in-the-field" settings.
- Up to 9,999,999
litres or US gallons
(non-resettable).
- Pulse output
for ancillary equipment.
- Long Life
3-volt Lithium / CR2040 battery. (Extended life
battery available as an option - see page
22).
- Approved for
hazardous locations (standard battery only) EEx
ia IIC T6 (PTB nr. Ex-93.C 4033X).
|
Mechanical
Display
|
>
Standard LC Display
>
Deluxe LC Display
>
Meters
>
Accessories
>
Top of page
|
The Mechanical
Display is available on specific
M4
M10
M40and
M50
Series meter models.
Features
- Litre or US
gallon display (according to model
selected).
- Two Total
displays; - 1 to 9,999 litres or 1/10 to 999.9
US gallons (Resettable) - 1 to 999,999 litres
(X10) or 1 to 999,999 US gallons
(Non-Resettable).
- Push button
reset.
- Display can be
rotated in 90° steps.
|
|