PCFPU280/70-U Bladder, Diaphragm & Piston Accumulator Charging & Testing Kit

Nitrogen accumulator charging kit for charging or pressure checking with Hydac style M28x1.5 female threaded accumulator valves, with a hexagon valve key. 400 bar maximum pressure (limited by charging device) with Hydrotechnik Minimess® test or charging points and charging hose.

  • Valve body complete with M28x1.5 female ring nut connection to accumulator gas valve, bleed and Minimess® charging hose connection.
  • Additional accumulator charging valve adaptors to 5/8" UNF female, 7/8" UNF female (long & short thread), 5/16" UNEF (VG8) female (long & short thread), 1/4" BSP female & Minimess® 1615 or 1620 female
  • 2.5m long high-pressure flexible microbore hose complete with Minimess® connections
  • Two pressure gauges (60 bar and 250 bar)
  • 5/8" BSP male adaptor to connect to nitrogen bottle with Minimess® charging hose connection
  • Set of spare gaskets
  • Carrying case

Measuring Kit Part Code

PCFPU-XXX-Y-Z-A
Pressure Gauges
(full scale range in Bar)
*Replace XXX with
250 & 60 bar
(standard)
280/70
400 bar 400
100 bar 100
40 bar 40
10 bar 10

Other ranges available on request.

Connection to Accumulator *Replace Y with
 M28x1.5 female
(standard)
X
5/8"-18 UNF female A
5/16"-32 UNEF / VG8 female (short) B
5/16"-32 UNEF / VG8 female (long) C
7/8"-14 UNF female (short) D
7/8"-14 UNF female (long with pin) E
1/4" BSP female (with pin) F
Minimess 1615 G
Minimess 1620 H
Universal (all of the above) U
Connection to Nitrogen Bottle *Replace Z with
5/8" BSP male
(standard)
X
W24,32x1/14" female W
W21,7x1/14" female M
CGA580 male A
W30x2 Nevoc female N

Other country Nitrogen bottle adaptors on request.

Connection to Nitrogen Bottle *Replace A with
2.5m (standard) 2.5
5m 5
10m 10

Other lengths available on request.

Further information

To get the most out of our range of accumulator charging and testing kits we have written the following articles.

Contact Us

Gas charging