Use these modules to connect additional analogue sensors. The sensor signals are digitised and transmitted via CAN bus to the measuring instrument. Each MultiXtend A provides four additional analogue inputs for connecting sensors with 0...20mA or 4...20mA signal output to your MultiSystem 4070, MultiSystem 5060plus, MultiSystem 5070 or MultiSystem 8050 series data loggers.
These may be connected in series to create a CAN bus line with, in theory, almost limitless extra channels.
Input connector type | Input signal | Order code |
---|---|---|
Cable glands | 0...20mA | |
M16 6-pin female | 0...20mA | |
Cable glands | 4...20mA | |
M16 6-pin female | 4...20mA |
Accessories | Order code |
---|---|
MultiXtend connection cable for MultiSystem 8050 (5m) | |
MultiXtend connection cable for MultiSystem 5060 (not plus) (5m) | |
MultiXtend connection cable for MultiSystem 4010, 5060plus and 5070 (5m) |
|
MultiXtend power supply |