PR110 series standard pressure test sensor - mA, V & kHz outputs

The HySense PR110 (formerly known as HT-PD) is our most popular pressure sensor for mobile hydraulic testing applications. Also popular in stationary industrial applications, it is available from -1...1000 bar and comes with a 5 pin connection.

  • Measuring ranges: from -1...1000 bar.
  • Mechanical connection: G1/4".
  • Signal output: 0...20mA, 4...20mA, 0...10V & 0.2...1.6kHz options.
  • Electrical connection: M16x0.75 6-pin.
  • Accuracy: <±0.5%.
  • 5-point calibration certificate available on request.
PR100Part Code by Signal Output
Measuring Range (bar)0...10V2 wire 4...20mA3 wire 0...20mA0.2...1.6kHz
-1...63403-32-C3.393403-32-C3.373403-32-C3.333403-32-C3.41
0...603403-21-C3.393403-21-C3.373403-21-C3.333403-21-C3.41
0...2503403-17-C3.393403-17-C3.373403-17-C3.333403-17-C3.41
0...4003403-15-C3.393403-15-C3.373403-15-C3.333403-15-C3.41
0...6003403-18-C3.393403-18-C3.373403-18-C3.333403-18-C3.41
0...10003403-29-C3.393403-29-C3.373403-29-C3.333403-29-C3.41